SIGMA CHEMICAL CO -- HYDROGEN PEROXIDE PH EUR 30%, 92302 -- 6810-00N072059
===================== Product Identification ===================== Product ID:HYDROGEN PEROXIDE PH EUR 30%, 92302 MSDS Date:01/31/1995 FSC:6810 NIIN:00N072059 === Responsible Party === Company Name:SIGMA CHEMICAL CO Box:14508 City:ST LOUIS State:MO ZIP:63178 Country:US Info Phone Num:314-771-5765 Emergency Phone Num:516-467-3535 CAGE:21076 === Contractor Identification === Company Name:SIGMA CHEMICAL COMPANY Address:3050 SPRUCE ST Box:14508 City:ST LOUIS State:MO ZIP:63178 Country:US Phone:314-771-5765 CAGE:21076 ============= Composition/Information on Ingredients ============= Ingred Name:HYDROGEN PEROXIDE, 30%; (HYDROGEN PEROXIDE) (SARA 302) CAS:7722-84-1 RTECS #:MX0899000 Fraction by Wt: 30% OSHA PEL:1 PPM ACGIH TLV:1 PPM ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50 (ORAL RAT): 1518 MG/KG. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE: MAY BE HARMFUL BY INHAL, INGEST/SKIN ABSORPTION. VAP/MIST IS IRRIT TO EYES, MUC MEMB & UPPER RESP TRACT. CAUSES SKIN IRRIT. CHRONIC: LAB EXPERIMENTS HAVE SHOWN MUTAGENIC EFTS. TO THE BEST OF MF R KNOWLEDGE, THE CHEM, PHYSICAL, & TOXICOLOGICAL PROPERTIES HAVE NOT BEEN THORO INVESTIGATED. (EFTS OF OVEREXPOSURE) Explanation of Carcinogenicity:NOT RELEVANT. Effects of Overexposure:HLTH HAZ: TARGET ORGAN DATA: BEHAVIORAL (SOMNOLENCE). Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:EYES: IMMEDIATELY FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN: IMMEDIATELY FLUSH WITH SOAP AND COPIOUS AMOUNTS OF WATER. INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE A RTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. INGESTION: WASH OUT MOUTH WITH WATER PROVIDED PERSON IS CONSCIOUS. CALL MD. WASH CONTAMINATED CLOTHING BEFORE REUSE. ===================== Fire Fighting Measures ===================== Flash Point:NONE Extinguishing Media:USE WATER SPRAY. Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS. ================== Accidental Release Measures ================== Spill Release Procedures:WEAR NIOSH APPROVED RESPIRATOR, CHEMICAL SAFETY GOGGLES, RUBBER BOOTS AND HEAVY RUBBER GLOVES. ABSORB ON SAND OR VERMICULITE AND PLACE IN CLOSED CONTAINERS FOR DISPOSAL. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT BREATHE VAPOR. AVOID CONTACT WITH EYES, SKIN AND CLOTHING. AVOID PROLONGED OR REPEATED EXPOSURE. KEEP TIGHTLY CLOSED. Other Precautions:PROTECT FROM LIGHT. REFRIGERATE. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:WEAR APPROPRIATE NIOSH APPROVED RESPIRATOR. Ventilation:MECHANICAL EXHAUST REQUIRED. Protective Gloves:CHEMICAL-RESISTANT GLOVES. Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS . Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA . PROTECTIVE CLOTHING. Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. Supplemental Safety and Health WASTE DISPSAL METHOD: OR MOLYBDENUM ARE PRESENT ADJUST PH OF SOLUTION TO 7 AND TREAT W/SULFIDE TO PRECIPITATE FOR BURIAL AS HAZARDOUS WASTE. DESTROY EXCESS SULFIDE, NEUTRALIZE & FLUSH SOLUTION DOWN T HE DRAIN. OBSERVE ALL FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS. ================== Physical/Chemical Properties ================== Vapor Pres:23.3 @ 30C Vapor Density:1 Spec Gravity:1.110 Appearance and Odor:COLORLESS LIQUID ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES REDUCING AGENTS, BRASS, COPPER, COPPER ALLOYS, GALVANIZED IRON, ZINC, NICKEL, LEAD, RUST, IRON & IRON SALTS, FINELY POWDERED METALS. Stability Condition to Avoid:SENSITIVE TO LIGHT. Hazardous Decomposition Products:OXYGEN, WATER. ==================== Disposal Considerations ==================== Waste Disposal Methods:CAUTIOUSLY ACIDIFY A 3% SOLN/SUSPENSION OF MATL TO PH 2 W/SULFURIC ACID. GRADUALLY ADD A 50% EXCESS OF AQUEOUS SODIUM BISULFITE W/STIRRING AT ROOM TEMP. AN INCR IN TEMP INDICATES THAT A RXN IS TAKING PLACE. IF NO RXN IS OBSERVED ON ADDN OF ABOUT 10% OF SODIUM BISULFITE SOLN INITIATE IT BY CAUTIOUSLY ADDING MORE ACID. IF MANGANESE, CHROMIUM (SUPDAT) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.