MALLINCKRODT, INC., SCIENCE PRODS DIV -- FORMIC ACID 88% -- 6810-00F013162
===================== Product Identification ===================== Product ID:FORMIC ACID 88% MSDS Date:07/13/1987 FSC:6810 NIIN:00F013162 === Responsible Party === Company Name:MALLINCKRODT, INC., SCIENCE PRODS DIV Box:M City:PARIS State:KY ZIP:43061 Info Phone Num:(34) 982-5000 Emergency Phone Num:(34) 982-5000 CAGE:DO886 === Contractor Identification === Company Name:MALLINCKRODT SPECIALTY CHEMICALS CO Address:222 RED SCHOOL LANE Box:City:PHILLIPSBURG State:NJ ZIP:08865 Country:US Phone:908-859-2151 CAGE:62910 Company Name:MALLINCKRODT, INC. Address:NONE SPECIFIED BY MANUFACTURER. Box:M City:PARIS State:KY ZIP:40361 Country:US Phone:314-982-5000 CAGE:DO886 ============= Composition/Information on Ingredients ============= Ingred Name:FORMIC ACID (SARA III) CAS:64-18-6 RTECS #:LQ4900000 Fraction by Wt: 88% Other REC Limits:5 PPM=IC OSHA PEL:5 PPM ACGIH TLV:5 PPM/10 STEL; 9192 EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS ===================== Hazards Identification ===================== LD50 LC50 Mixture:ORAL RAT LD50 = 1100 MG/KG Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:SKIN: DANGER/CORROSIVE. LIQUID & MIST CAUSE SEVERE BURNS TO ALL BODY TISSUE. INGESTION: FATAL/HARMFUL. INHALATION: LUNG DAMAGE. COMBUSTIBLE. Explanation of Carcinogenicity:NONE Effects of Overexposure:SKIN: DANGER/CORROSIVE. LIQUID/MIST CAUSE SEVERE BURNS TO ALL BODY TISSUE. INGESTION: FATAL/HARMFUL. INHALATION: LUNG DAMAGE. COMBUSTIBLE. ======================= First Aid Measures ======================= First Aid:INGESTION: DON'T INDUCE VOMITING. GIVE LARGE QUANTITIES OF WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. INHALTION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN.SKIN/EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. ===================== Fire Fighting Measures ===================== Flash Point Method:CC Flash Point:122F Lower Limits:18% Upper Limits:57% Extinguishing Media:DRY CHEMICAL, FOAM, OR CO2. Fire Fighting Procedures:WATER SPRAY MAY BE USED TO KEEP FIRE EXPOSED CONTAINERS COOL. IN THE EVENT OF A FIRE, WEAR FULL PROTECTIVE CLOTHING/NIOSH-APPROVED SCBA W/FULL FACEPIECE. Unusual Fire/Explosion Hazard:ABOVE FLASH POINT, VAPOR-AIR MIXTURES ARE EXPLOSIVE WITHIN FLAMMABLE LIMITS. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA OF LEAK OR SPILL. REMOVE ALL SOURCES OF IGNITION. CLEAN-UP PERSONNEL REQUIRE PROTECTIVE CLOTHING/RESPIRATORY PROTECTION FROM VAPORS. CONTAIN/RECOVER LIQUID WHEN POSSIBLE. DON'T FLUSH TO SEWER. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP IN A TIGHTLY CLOSED CONTAINER. STORE IN A COOL, DRY VENTILATED AREA AWAY FROM SOURCES OF HEAT/IGNITION. PROTECT AGAINST PHYSICAL DAMAGE. Other Precautions:SHOULD BE HANDLED IN 316 STAINLESS STEEL, GLASS, CERAMIC, OR SIMILAR CORROSION RESISTANT MATERIALS. AVOID CONTACT W/EYES, SKIN, CLOTHING/BREATHING MIST. KEEP CONTAINER CLOSED. USE W/ADEQUATE VENTILATI ON. WASH THOROUGHLY AFTER HANDLING. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF THE TLV IS EXCEEDED A FULL FACEPIECE CHEMICAL CARTRIDGE RESPIRATOR MAY BE WORN, IN GENERAL, UP TO 100 TIMES THE TLV OR THE MAXIMUM USE CONCENTRATION SPECIFIED BY THE RESPIRATOR SUPPLIER, WHICHEVER IS LESS. Ventilation:A SYSTEM OF LOCAL EXHAUST/MECHANICAL IS RECOMMENDED TO KEEP