MALLINCKRODT, INC., SCIENCE PRODS DIV -- FORMIC ACID 88% -- 6810-00F013162
===================== Product Identification =====================
Product ID:FORMIC ACID 88%
MSDS Date:07/13/1987
FSC:6810
NIIN:00F013162
=== Responsible Party ===
Company Name:MALLINCKRODT, INC., SCIENCE PRODS DIV
Box:M
City:PARIS
State:KY
ZIP:43061
Info Phone Num:(34) 982-5000
Emergency Phone Num:(34) 982-5000
CAGE:DO886
=== Contractor Identification ===
Company Name:MALLINCKRODT SPECIALTY CHEMICALS CO
Address:222 RED SCHOOL LANE
Box:City:PHILLIPSBURG
State:NJ
ZIP:08865
Country:US
Phone:908-859-2151
CAGE:62910
Company Name:MALLINCKRODT, INC.
Address:NONE SPECIFIED BY MANUFACTURER.
Box:M
City:PARIS
State:KY
ZIP:40361
Country:US
Phone:314-982-5000
CAGE:DO886
============= Composition/Information on Ingredients =============
Ingred Name:FORMIC ACID (SARA III)
CAS:64-18-6
RTECS #:LQ4900000
Fraction by Wt: 88%
Other REC Limits:5 PPM=IC
OSHA PEL:5 PPM
ACGIH TLV:5 PPM/10 STEL; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL RAT LD50 = 1100 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: DANGER/CORROSIVE. LIQUID & MIST
CAUSE SEVERE BURNS TO ALL BODY TISSUE. INGESTION: FATAL/HARMFUL.
INHALATION: LUNG DAMAGE. COMBUSTIBLE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: DANGER/CORROSIVE. LIQUID/MIST CAUSE
SEVERE BURNS TO ALL BODY TISSUE. INGESTION: FATAL/HARMFUL.
INHALATION: LUNG DAMAGE. COMBUSTIBLE.
======================= First Aid Measures =======================
First Aid:INGESTION: DON'T INDUCE VOMITING. GIVE LARGE QUANTITIES OF
WATER. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
INHALTION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN.SKIN/EYES:
FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:122F
Lower Limits:18%
Upper Limits:57%
Extinguishing Media:DRY CHEMICAL, FOAM, OR CO2.
Fire Fighting Procedures:WATER SPRAY MAY BE USED TO KEEP FIRE EXPOSED
CONTAINERS COOL. IN THE EVENT OF A FIRE, WEAR FULL PROTECTIVE
CLOTHING/NIOSH-APPROVED SCBA W/FULL FACEPIECE.
Unusual Fire/Explosion Hazard:ABOVE FLASH POINT, VAPOR-AIR MIXTURES ARE
EXPLOSIVE WITHIN FLAMMABLE LIMITS.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA OF LEAK OR SPILL. REMOVE ALL
SOURCES OF IGNITION. CLEAN-UP PERSONNEL REQUIRE PROTECTIVE
CLOTHING/RESPIRATORY PROTECTION FROM VAPORS. CONTAIN/RECOVER LIQUID
WHEN POSSIBLE. DON'T FLUSH TO SEWER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP IN A TIGHTLY CLOSED CONTAINER.
STORE IN A COOL, DRY VENTILATED AREA AWAY FROM SOURCES OF
HEAT/IGNITION. PROTECT AGAINST PHYSICAL DAMAGE.
Other Precautions:SHOULD BE HANDLED IN 316 STAINLESS STEEL, GLASS,
CERAMIC, OR SIMILAR CORROSION RESISTANT MATERIALS. AVOID CONTACT
W/EYES, SKIN, CLOTHING/BREATHING MIST. KEEP CONTAINER CLOSED. USE
W/ADEQUATE VENTILATI ON. WASH THOROUGHLY AFTER HANDLING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF THE TLV IS EXCEEDED A FULL FACEPIECE CHEMICAL
CARTRIDGE RESPIRATOR MAY BE WORN, IN GENERAL, UP TO 100 TIMES THE
TLV OR THE MAXIMUM USE CONCENTRATION SPECIFIED BY THE RESPIRATOR
SUPPLIER, WHICHEVER IS LESS.
Ventilation:A SYSTEM OF LOCAL EXHAUST/MECHANICAL IS RECOMMENDED TO KEEP