MITCO MFG INC -- SID HARVEY HURRI-CLEAN SUPER CONCENTRATE, F1-28 -- 6850-00N044894
=====================  Product Identification  =====================

Product ID:SID HARVEY HURRI-CLEAN SUPER CONCENTRATE, F1-28
MSDS Date:03/02/1992
FSC:6850
NIIN:00N044894
=== Responsible Party ===
Company Name:MITCO MFG INC
Address:317 NEW SOUTH RD
City:HICKSVILLE
State:NY
ZIP:11801
Country:US
Info Phone Num:516-935-4417
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:70180
=== Contractor Identification ===
Company Name:MITCO MFG INC
Address:317 NEW SOUTH RD
Box:City:HICKSVILLE
State:NY
ZIP:11801
Country:US
Phone:516-935-4430
CAGE:70180

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM HYDROXIDE (CERCLA)
CAS:1310-73-2
RTECS #:WB4900000
Fraction by Wt: <3.0%
OSHA PEL:2 MG/M3
ACGIH TLV:C 2 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:SILICIC ACID (H2SIO3), DISODIUM DALT; (SODIUM METASILICATE)
CAS:6834-92-0
RTECS #:VV9275000
Fraction by Wt: <5.0%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL)
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: <3.0%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:NOT APPLICABLE. MEDIA SUITABLE FOR SURROUNDING FIRE
    .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

=============  Exposure Controls/Personal Protection  =============

Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.0588
pH:11.9
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:COMPLETE
Appearance and Odor:FLOURESCENT GREEN LIQUID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:DO NOT MIX WITH ACIDS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.