SIGMA CHEMICAL COMPANY -- 109207 2-METHYL-2-PROPANETHIOL 99% -- 6850-00F056221
=====================  Product Identification  =====================

Product ID:109207 2-METHYL-2-PROPANETHIOL 99%
MSDS Date:01/01/1997
FSC:6850
NIIN:00F056221
=== Responsible Party ===
Company Name:SIGMA CHEMICAL COMPANY
Address:3050 SPRUCE ST
Box:14508
City:SAINT LOUIS
State:MO
ZIP:63178-5000
Country:US
Info Phone Num:314-771-5765/800-325-3010
Emergency Phone Num:314-771-5765/800-325-3010
CAGE:21076
=== Contractor Identification ===
Company Name:SIGMA CHEMICAL COMPANY
Address:3050 SPRUCE ST
Box:14508
City:ST LOUIS
State:MO
ZIP:63178
Country:US
Phone:314-771-5765
CAGE:21076

=============  Composition/Information on Ingredients  =============

Ingred Name:T-BUTYL MERCAPTAN
CAS:75-66-1
RTECS #:TZ7660000
Fraction by Wt: 99%

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50(RAT): 4729 MG/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:HARMFUL IF INHALED/SWALLOWED.
    INHALATION: MAY BE IRRITATING TO THE EYES, MUCOUS MEMBRANES & UPPER
    RESPIRATORY TRACT. CAUSES SKIN IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, NAUSEA, HEADACHE, VOMITING

=======================  First Aid Measures  =======================

First Aid:SKIN: WASH W/SOAP & COPIOUS AMOUNTS OF WATER. EYES:
    IMMEDIATELY FLUSH W/COPIOUS AMOUNTS OF WATER FOR 15 MINS.
    INHALATION: REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF NECESSARY.
    INGESTION: WASH OUT MOUTH W /WATER IF CONSCIOUS. OBTAIN MEDICAL
    ATTENTION IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point:-12F
Extinguishing Media:CO2, DRY CHEMICAL POWDER/APPROPRIATE FOAM. WATER
    MAY BE EFFECTIVE FOR COOL, BUT MAY NOT EFFECT EXTINGUISHMENT.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS &
    PROTECTIVE CLOTHING TO PREVENT CONTACT W/SKIN & EYES. USE WATER
    SPRAY TO COOL FIRE-EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:VAPOR MAY TRAVEL CONSIDERABLE DISTANCE TO
    SOURCE OF IGNITION & FLASH BACK. CONTAINER EXPLOSION MAY OCCUR
    UNDER FIRE CONDITIONS.			(SEE SUPP)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA. WEAR SCBA, RUBBER BOOTS & HEAVY
    RUBBER GLOVES. SHUT OFF ALL IGNITION SOURCES. COVER W/AN ACTIVATED
    CARBON ABSORBENT, TAKE UP & PLACE IN CLOSED CONTAINERS. TRANSPORT
    OUTDOORS. VENTILATE  AREA & WASH SITE AFTER PICKUP IS COMPLETE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE AWAY FROM
    IGNITION SOURCES. KEEP CONTAINER TIGHTLY CLOSED. WEAR SUITABLE
    PROTECTIVE CLOTHING, GLOVES, EYE/FACE PROTECTION.
Other Precautions:DON'T BREATHE VAPOR. DON'T GET IN EYES, ON SKIN/ON
    CLOTHING. AVOID PROLONGED/REPEATED EXPOSURE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING, SAFETY SHOWER, EYE BATH
Work Hygienic Practices:REMOVE/DISCARD CONTAMINATED CLOTHING & SHOES.
    WASH THOROUGHLY AFTER HANDLING. NO SMOKING.
Supplemental Safety and Health
FIRE HAZ CONT'D: EMITS TOXIC FUMES UNDER FIRE CONDITIONS. FORMS
    EXPLOSIVE MIXTURES IN AIR.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:143.6-149F
Vapor Pres:303.5
Vapor Density:3.1
Spec Gravity:0.8
Appearance and Odor:COLORLESS LIQUID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
BASES, OXIDIZING AGENTS, REDUCING AGENTS, ALKALI METALS
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME & OTHER IGNITION
    SOURCES, STENCH
Hazardous Decomposition Products:CO, CO2, SULFUR OXIDES, HYDROGEN
    SULFIDE GAS

====================  Disposal Considerations  ====================

Waste Disposal Methods:BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AN
    AFTERBURNER & SCRUBBER BUT EXERT CARE IN IGNITING AS THIS MATERIAL
    IS HIGHLY FLAMMABLE. DISPOSE OF IAW/LOCAL, STATE & FEDERAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.