HACH CO. -- NESSLER REAGENT -- 6810-01-011-7192
===================== Product Identification ===================== Product ID:NESSLER REAGENT MSDS Date:06/12/1991 FSC:6810 NIIN:01-011-7192 === Responsible Party === Company Name:HACH CO. Box:907 City:AMES State:IA ZIP:50010 Country:US Info Phone Num:800-227-4224/303-669-3050 Emergency Phone Num:800-227-4224 OR 303-623-5716 SUPP. CAGE:4T252 === Contractor Identification === Company Name:ADVANCED INDUSTRIES INC Address:415 NORTHCUTT STREET Box:5666 City:LONGVIEW State:TX ZIP:75608 Country:US Phone:214-236-4101 CAGE:0GA21 Company Name:HACH COMPANY Address:100 DAYTON RD. Box:907 City:AMES State:IA ZIP:50010 Country:US Phone:800-227-4224 CAGE:4T252 ============= Composition/Information on Ingredients ============= Ingred Name:MERCURIC IODIDE CAS:7774-29-0 RTECS #:OW5250000 Fraction by Wt: < 15% Other REC Limits:NONE SPECIFIED OSHA PEL:0.1 MG/M3 AS HG, MFR ACGIH TLV:0.05 MG/M3 AS HG,MFR Ingred Name:SODIUM HYDROXIDE (SARA III) CAS:1310-73-2 RTECS #:WB4900000 Fraction by Wt: < 20% Other REC Limits:NONE SPECIFIED OSHA PEL:2 MG/M3 ACGIH TLV:C 2 MG/M3; 9293 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:SODIUM IODIDE CAS:7681-82-5 RTECS #:WB6475000 Fraction by Wt: < 10% Other REC Limits:NONE SPECIFIED Ingred Name:IODINE CAS:7553-56-2 RTECS #:NN1575000 Fraction by Wt: < 1% Other REC Limits:NONE SPECIFIED OSHA PEL:C 0.1 PPM ACGIH TLV:C 0.1 PPM; 9192 Ingred Name:WATER, DEMINERALIZED CAS:7732-18-5 RTECS #:ZC0110000 Fraction by Wt: TO 100% Other REC Limits:NONE SPECIFIED ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE-MAY BE CORROSIVE TO EYES AND SKIN. VERY TOXIC. OVEREXPOSURE CAUSES BURNS. CHRONIC- CUMULATIVE POISON. Effects of Overexposure:SEE HEALTH HAZARDS SECTION. Medical Cond Aggravated by Exposure:MAY AGGRAVATE ALLERGIES OR SENSITIVITY TO MERCURY; EYE OR SKIN CONDITIONS; DISORDERS OF THE CENTRAL NERVOUS SYSTEM OR KIDNEY. ======================= First Aid Measures ======================= First Aid:EYE AND SKIN CONTACT:IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES.REMOVE CONTAMINATED CLOTHING.CALL PHYSICIAN.INHALATION:REMOVE TO FRESH AIR.CALL PHYSICIAN.INGESTED:DO NOT INDUCE VOMITING.IF CONSCIOUS, DRINK 1-2 GLASSES OF WATER.CALL A PHYSICIAN IMMEDIATELY. ===================== Fire Fighting Measures ===================== Flash Point:NOT RELEVANT Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE. Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SELF CONTAIED BREATHING APPARATUS & FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE PRODUCTION OF TOXIC FUMES. ================== Accidental Release Measures ================== Spill Release Procedures:DO NOT ALLOW THE MERCURY CONTAMINATE AIR OR WATER. SOAK UP SOLUTION WITH INERT MATERIAL. DO NOT BREATHE FUMES. DECONTAMINATE AREA WITH MERCURY ABSORBING COMPOUNDS AVAILABLE COMMERCIALLY. Neutralizing Agent:NOT GIVEN ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE TIGHTLY CLOSED. Other Precautions:WASH THOROUGHLY AFTER HANDLING. AVOID CONTACT WITH EYES, SKIN AND CLOTHING. DO NOT BREATHE FUMES OR VAPORS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH APPROVED AIR SUPPLIED RESPIRATOR IF NEEDED. Ventilation:USE MECHANICAL (GENERAL) OR LOCAL EXHAUST VENTILATION TO MEET TLV REQUIREMENTS. Protective Gloves:RUBBER GLOVES Eye Protection:SAFETY GOGGLES WITH OPTIONAL FACE SHIELD Other Protective Equipment:EYE WASH STATION, SAFETY SHOWER, FUME HOOD, LAB GRADE GOGGLES, DISPOSABLE GLOVES, LAB COAT. Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICE. AVOID ALL CONTACT IF POSSIBLE. Supplemental Safety and Health FORMULATION CHANGED. FOR PREVIOUS FORMULATION, SEE P/N A, SAME NSN. ================== Physical/Chemical Properties ================== HCC:B1 Spec Gravity:1.265 pH:12.1 Solubility in Water:MISCIBLE Appearance and Odor:CLEAR, LIGHT YELLOW LIQUID Corrosion Rate:4.245 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ACIDS, ORGANICS, AMMONIA, ALDEHYDES Stability Condition to Avoid:EXTREME TEMPERATURES AND LIGHT Hazardous Decomposition Products:TOXIC FUMES OF MERCURY, IODINE AND IODINE COMPOUNDS ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF ALL MERCURY CONTAMINATED MATERIAL IN AN EPA APPROVED HAZARDOUS WASTE FACILITY. DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.