CHEM SERVICE INC -- DIPENTENE, O-750 -- 6810-00N067851
===================== Product Identification =====================
Product ID:DIPENTENE, O-750
MSDS Date:09/01/1988
FSC:6810
NIIN:00N067851
=== Responsible Party ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Info Phone Num:215-692-3026
Emergency Phone Num:215-692-3026
CAGE:84898
=== Contractor Identification ===
Company Name:CHEM SERVICE INC
Box:3108
City:WEST CHESTER
State:PA
ZIP:19381
Country:US
Phone:215-692-3026
CAGE:84898
Company Name:CHEM SERVICE, INC
Address:660 TOWER LN
Box:599
City:WEST CHESTER
State:PA
ZIP:19301-9650
Country:US
Phone:610-692-3026
CAGE:8Y898
============= Composition/Information on Ingredients =============
Ingred Name:BIBENZYL; (DIPENTENE)
CAS:138-86-3
RTECS #:OS8100000
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50: (RAT) 5000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS - AVOID DIRECT PHYSICAL CONTACT! CAN CAUSE SKIN
IRRITATION. CAN BE IRRITATING TO MUCOUS MEMBRANES. CAN CAUSE EYE
IRRITATION. CAN BE HARMFUL IF ABSORBED THR OUGH THE SKIN. CAN BE
HARMFUL IF INHALED. CAN BE HARMFUL IF SWALLOWED.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF POISON.
IT SHOULD BE ADMIN ONLY BY MD/TRAINED EMER PERS. MED ADVICE CAN BE
OBTAINED FROM POIS CTL CTR. EYES:FLUSH CONTINUOUSLY W/WATER FOR AT
LEAST 15-20 MIN. SKIN: FLUSH W/WATER FOR 15-20 MIN. IF NO BURNS
HAVE OCCURRED-USE SOAP & WATER TO CLEANSE SKIN. INHAL: REMOVE TO
FRESH AIR. ADMIN OXYGEN IF HAVING DFCLTY BRTHG. IF BRTHG HAS
STOPPED (SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point:108F,42C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER OR WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS IS A COMBUSTIBLE COMPOUND.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE AREA. WEAR APPROPRIATE OSHA-REGULATED
EQUIPMENT. VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR
MATERIAL. SWEEP UP AND PLACE IN AN APPROPRIATE CONTAINER. HOLD FOR
DISPOSAL. WASH CONTAMINATE D SURFACES TO REMOVE ANY RESIDUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES AND
CLOTHING. KEEP TIGHTLY CLOSED AND STORE IN A COOL, DRY PLACE. STORE
ONLY WITH COMPATIBLE CHEMICALS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
NOT HANDLE THIS CHEM OR ITS CNTNR. THIS PROD IS FURNISHED FOR LAB
USE ONLY! PRODS MAY NOT BE USED AS DRUGS, COSMETICS,
AGRICULTURAL/PESTICIDAL PRODS, FOOD ADDITIVES OR AS HOUSEHOLD
CHEMS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:THIS CHEMICAL SHOULD BE HANDLED ONLY IN A HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . USE
APPROPRIATE OSHA/MSHA APPROVED SAFETY EQUIPMENT.
Work Hygienic Practices:CONTACT LENSES SHOULD NOT BE WORN IN THE
LABORATORY.
Supplemental Safety and Health
FIRST AID PROC: ADMIN ARTF RESP. IF IN CARD ARREST ADMIN CPR. CONTINUE
LIFE SUPPORTING MEASURES UNTIL MED ASSISTANCE HAS ARRIVED. INGEST:
CALL MD IMMEDIATELY .
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:352F,178C
Spec Gravity:0.840
Solubility in Water:INSOL (IMMISCIBLE)
Appearance and Odor:COLORLESS LIQUID.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EASILY OXIDIZED-MAY BE A PEROXIDE
FORMER-CHECK FOR PEROXIDES ON ALL OPENED SAMPLES. FLAMMABLE.
Hazardous Decomposition Products:DECOMPOSITION LIBERATES TOXIC FUMES.
DECOMPOSITION PRODUCTS ARE CORROSIVE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . BURN IN A CHEMICAL INCINERATOR
EQUIPPED WITH AN AFTERBURNER AND SCRUBBER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.