CAROLINA BIOLOGICAL SUPPLY CO -- METHANOL, SYNTHETIC (SEE SUPPLEMENTAL DATA) -- -
===================== Product Identification ===================== Product ID:METHANOL, SYNTHETIC (SEE SUPPLEMENTAL DATA) MSDS Date:09/05/2000 FSC:NIIN:Submitter:D DG Status Code:A === Responsible Party === Company Name:CAROLINA BIOLOGICAL SUPPLY CO Address:2700 YORK RD City:BURLINGTON State:NC ZIP:27215-3387 Country:US Info Phone Num:800-227-1150/910-584-0381 Emergency Phone Num:(800)424-9300 Chemtrec Ind/Phone:(800)424-9300 CAGE:59896 === Contractor Identification === Company Name:CAROLINA BIOLOGICAL SUPPLY CO Address:2700 YORK RD Box:City:BURLINGTON State:NC ZIP:27215-3387 Country:US Phone:800-227-1150/910-584-0381 Contract Num:MDA414-01-P-2014 CAGE:59896 ============= Composition/Information on Ingredients ============= Ingred Name:METHANOL CAS:67-56-1 RTECS #:PC1400000 Minumum % Wt:90. Maxumum % Wt:100. OSHA PEL:260 MG/M3;200 PPM ACGIH TLV:262 MG/M3;200 PPM ACGIH STEL:328 MG/M3;250 PPM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:UNKNOWN Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:HUMAN POISON BY INGESTION. MILDLY TOXIC BY INHALATION. EYES: MAY CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE GASTROINTESTINAL DISCOMFORT. INHALATION: MAY CAUSE IRRITATION TO RES PIRATORY TRACT. TARGET ORGANS: EYES, SKIN AND NERVOUS SYSTEM. Explanation of Carcinogenicity:MUTATION AND REPRODUCTIVE DATA CITED. NOT LISTED AS CAUSING CANCER. Effects of Overexposure:EYES: MAY CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE GASTROINTESTINAL DISCOMFORT. INHALATION: MAY CAUSE IRRITATION TO RESPIRATORY TRACT. Medical Cond Aggravated by Exposure:PREEXISTING CONDITIONS OF THE EYES, SKIN AND NERVOUS SYSTEM. ======================= First Aid Measures ======================= First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES, RAISING AND LOWERING EYELIDS OCCASIONALLY. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN: THOROUGHLY WASH EXPOSED AREA FOR AT LEAST 15 MINUTES. REMO VE CONTAMINATED CLOTHING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INGESTION: IF SWALLOWED, IF CONSCIOUS, GIVE PLENTY OF WATER AND INDUCE VOMITING IMME DIATELY AS DIRECTED BY MEDICAL PERSONNEL. IMMEDIATELY CALL A PHYSICIAN OR POISON CONTROL CENTER. NEVER GIVE ANTHING BY MOUTH TO AN UNCONSCIOUS PERSON. SEE SUPPLEMENTAL DATA. ===================== Fire Fighting Measures ===================== Flash Point:=12.2C, 54.F Autoignition Temp:=470.C, 878.F Lower Limits:7.3 Upper Limits:36 Extinguishing Media:USE DRY CHEMICAL, CO2 OR APPROPRIATE FOAM. Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE EQUIPMENT AND NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR AND CAN TRAVEL TO A SOURCE OF IGNITION AND FLASH BACK, ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA OF SPILL. ELIMINATE ALL SOURCES OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FROM AREA. CLEAN-UP PERSONNEL SHOULD WEAR PROPER PROTECTION EQUIPMENT AND CLOTHING. ABSORB MATERIAL WITH SUITABLE ABSORBENT AND CONTAINERIZE FOR DISPOSAL. ====================== Handling and Storage ====================== Handling and Storage Precautions:THIS MATERIAL SHOULD BE KEPT IN AN AREA SUITABLE FOR THE STORAGE OF HIGHLY FLAMMABLE LIQUIDS. BOND AND GROUND CONTAINERS WHEN TRANSFERRING LIQUID. Other Precautions:KEEP OXIDIZING MATERIALS AND STRONG ACIDS AWAY. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:A NIOSH/MSHA CHEMICAL CARTRIDGE RESPIRATOR SHOULD BE WORN IF PEL OR TLV IS EXCEEDED. Ventilation:LOCAL EXHAUST: PREFERRED, MECHANICAL (GENERAL) YES Protective Gloves:RUBBER, NEOPRENE, PVC, OR EQUIVALENT. Eye Protection:SPLASH PROOF CHEMICAL SAFETY GOGGLES Other Protective Equipment:LAB COAT, EYE WASH, AND SAFETY SHOWER. Supplemental Safety and Health P/N: 87-4913, 87-4915, 87-4950, 87-4954, 17-4100, 84-0490. FIRST AID CONT: INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING IS DIFFICULT; GIVE ARTIFICIAL RESPIRATION IF BREATHING HAS STOPPED . KEEP PERSON WARM, QUIET, AND GET MEDICAL ATTENTION. ================== Physical/Chemical Properties ================== HCC:F2 Boiling Pt:=65.C, 149.F Melt/Freeze Pt:=-97.8C, -144.F Vapor Pres:100 MM HG @21.2C Vapor Density:1.11 Spec Gravity:0.7915 Evaporation Rate & Reference:4.6 (H2O=1) Solubility in Water:MISCIBLE Appearance and Odor:CLEAR, COLORLESS, VOLATILE LIQUID, SLIGHT ALCOHOL ODOR. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZING AGENTS AND STRONG ACIDS. Stability Condition to Avoid:HEAT SPARKS, OPEN FLAME. Hazardous Decomposition Products:NO DATA AVAILABLE. Conditions to Avoid Polymerization:WILL NOT OCCUR. =================== Toxicological Information =================== Toxicological Information:TARGET ORGANS: EYES, SKIN & NERVOUS SYSTEM. PRIMARY ROUTE(S) OF ENTRY: INGESTION, INHALATION. ===================== Ecological Information ===================== Ecological:EPA WASTE NUMBERS: U154, D001. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE. =================== MSDS Transport Information =================== Transport Information:DESCRIPTION: METHANOL, 3, UN1230, II ===================== Regulatory Information ===================== SARA Title III Information:HAZARD CATEGORY FOR SARA SECTION 311/312 REPORTING: ACUTE, CHRONIC, FIRE. METHANOL: SARA 313 CHEMICALS- NAME LIST: YES. Federal Regulatory Information:EPA TSCA STATUS: ON TSCA INVENTORY. CERCLA SEC. 103 RQ 5000 LBS FOR METHANOL. METHANOL- RCRA SEC. 261.33 Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.